e-Shop Katalog

gold-plating bath

Note: Hazardous product

gold-plating bath Previous product2/2Next product

gold-plating bath

These baths are used for acid electrolyte for decorative gold-plating of non-ferrous metals and silver alloys with differing deposition alloy and thus colour. The range of materials able to be plated can be considerably increased by a preparatory application of the pre-plating gold bath AC3 (item No. 695655), e.g. steels

The bright gold-plating baths Quator are used in traditional electroplating units such as the WILAPLAT system. The pH value is adjusted when necessary either by citric acid or caustic soda. Before electroplating, surfaces to be treated must be cleaned, and free from grease or oil.

Technical Details:

Gold content 5.0 g/l
Temperature 55 - 60 °C
Exposure time 10 - 45 minutes
Voltage 1.6 - 2.0 volts
Current density 0.5 - 1.5 A/dm²
Deposition 30-40 mg/Amin
pH-value 3.5 - 4.5
Agitation electrolyte or goods movement
Anodes steel
Bath material glass, acid-resistant plastic

Density 15.5 g/cm³
Hardness 350 - 400 HV

Further details are to be found in the EEC – safety data sheets

namegold-plating bath

colour5N / Pink gold 5g

contents1 litre

Versionready for use

item No.695629